{"id":9706,"date":"2023-05-09T15:37:01","date_gmt":"2023-05-09T15:37:01","guid":{"rendered":"https:\/\/teqja.com.al\/?page_id=9706"},"modified":"2023-06-09T11:50:25","modified_gmt":"2023-06-09T11:50:25","slug":"laboratori","status":"publish","type":"page","link":"https:\/\/teqja.com.al\/en\/laboratori\/","title":{"rendered":"The laboratory"},"content":{"rendered":"<section class=\"wpb-content-wrapper\"><div class=\"vc-custom-col-spacing clearfix vc-col-spacing-30\"><section class=\"wpb_row vc_row-fluid row-content-position-Default\"><div class=\"bauer-container\"><div class=\"row-inner clearfix\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"bauer-simple-image text-center\" style=\"\" >\r\n\t\t\t<img decoding=\"async\" alt=\"image\" src=\"https:\/\/teqja.com.al\/wp-content\/uploads\/2023\/06\/lab-teqja.webp\" \/> \r\n\t\t<\/div>\r\n\t<div class=\"bauer-spacer clearfix\" data-desktop=\"40\" data-mobi=\"40\" data-smobi=\"40\"><\/div><\/div><\/div><\/div><\/div><\/div><\/section><\/div><div class=\"vc-custom-col-spacing clearfix vc-col-spacing-30\"><section class=\"wpb_row vc_row-fluid row-content-position-Default\"><div class=\"bauer-container\"><div class=\"row-inner clearfix\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><h2 class=\"bauer-text clearfix\" style=\"\"><p>Teqja International Laboratory<\/p>\n<\/h2><div class=\"bauer-text clearfix\" style=\"font-size:16px;\"><p>Teqja International Laboratory is a specialized environment which is used to test and monitor the quality of products. The laboratory is equipped with advanced technology and additional equipment to ensure that their products meet high quality and safety standards.<\/p>\n<p>Specialized technicians conduct a series of tests on plastic pipes to verify their quality and performance. These tests include measurements and tests for resistance to internal pressure, thickness, external diameter.<\/p>\n<p>Teqja Internacional Laboratory also provides specialized testing services to their customers, ensuring that their products are compliant with industry standards and customer requirements.<\/p>\n<\/div>\r\n\t<div class=\"bauer-spacer clearfix\" data-desktop=\"40\" data-mobi=\"40\" data-smobi=\"40\"><\/div><\/div><\/div><\/div><\/div><\/div><\/section><\/div><div class=\"vc-custom-col-spacing clearfix vc-col-spacing-30\"><section class=\"wpb_row vc_row-fluid row-content-position-Default\"><div class=\"bauer-container\"><div class=\"row-inner clearfix\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"bauer-simple-image text-center\" style=\"\" >\r\n\t\t\t<img decoding=\"async\" alt=\"image\" src=\"https:\/\/teqja.com.al\/wp-content\/uploads\/2023\/06\/lab-teqja-right-1.jpg\" \/> \r\n\t\t<\/div>\r\n\t<div class=\"bauer-spacer clearfix\" data-desktop=\"0\" data-mobi=\"30\" data-smobi=\"30\"><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"bauer-images-grid clearfix\" data-layout=\"mosaic\" data-column=\"1\" data-column2=\"1\" data-column3=\"1\" data-column4=\"1\" data-gaph=\"30\" data-gapv=\"0\"><div id=\"images-wrap\" class=\"cbp\"><div class=\"cbp-item\"><div class=\"item-wrap\" style=\"\"><a class=\"zoom-popup cbp-lightbox\" href=\"https:\/\/teqja.com.al\/wp-content\/uploads\/2023\/06\/WhatsApp-Image-2023-06-06-at-16.04.54.jpg\"><\/a><img decoding=\"async\" src=\"https:\/\/teqja.com.al\/wp-content\/uploads\/2023\/06\/WhatsApp-Image-2023-06-06-at-16.04.54-600x600.jpg\" alt=\"image\" \/><\/div><\/div><div class=\"cbp-item\"><div class=\"item-wrap\" style=\"\"><a class=\"zoom-popup cbp-lightbox\" href=\"https:\/\/teqja.com.al\/wp-content\/uploads\/2023\/06\/WhatsApp-Image-2023-06-06-at-16.04.55.jpg\"><\/a><img decoding=\"async\" src=\"https:\/\/teqja.com.al\/wp-content\/uploads\/2023\/06\/WhatsApp-Image-2023-06-06-at-16.04.55-600x600.jpg\" alt=\"image\" \/><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/section><\/div><div class=\"vc-custom-col-spacing clearfix vc-col-spacing-30\"><section class=\"wpb_row vc_row-fluid row-content-position-Default\"><div class=\"bauer-container\"><div class=\"row-inner clearfix\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\r\n\t<div class=\"bauer-spacer clearfix\" data-desktop=\"80\" data-mobi=\"80\" data-smobi=\"80\"><\/div><div class=\"bauer-content-box clearfix\" ><div class=\"vc-custom-col-inner-spacing clearfix vc-col-inner-spacing-0px\"><div class=\"wpb_row vc_inner vc_row-fluid vc_custom_1681388320571 vc_row-has-fill\"><div class=\"wpb_column vc_column_container vc_col-sm-12 vc_col-has-fill\"><div class=\"vc_column-inner vc_custom_1681456558069\"><div class=\"wpb_wrapper\"><div class=\"bauer-text clearfix text-center\" style=\"font-weight:700;font-size:15px;color:#ffffff;\"><div style=\"border-bottom: 3px solid #f2e201; padding: 10px 0;\">List of Laboratory Tests<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"bauer-content-box clearfix\" ><div class=\"vc-custom-col-inner-spacing clearfix vc-col-inner-spacing-30\"><div class=\"wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\r\n\t<div class=\"bauer-spacer clearfix\" data-desktop=\"40\" data-mobi=\"40\" data-smobi=\"40\"><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"bauer-content-box clearfix\" ><div class=\"vc-custom-col-inner-spacing clearfix vc-col-inner-spacing-20\"><div class=\"wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><h6 class=\"bauer-text clearfix\" style=\"\"><table class=\"eg-table\" width=\"580\" height=\"858\">\n<tbody>\n<tr>\n<th>Test description<\/th>\n<th>Standard<\/th>\n<\/tr>\n<tr>\n<td>Thermoplastics pipes \u2013 Determination of ring stiffness<\/td>\n<td>EN ISO 9969 &#8211; 2016<\/td>\n<\/tr>\n<tr>\n<td>Plastics piping systems for non- pressure underground drainage and sewerage \u2013 Structured \u2013 wall piping systems of unplaticized poly (vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) \u2013 General requirements and performance characteristics.<\/td>\n<td>EN 13476-1:2018<\/td>\n<\/tr>\n<tr>\n<td>Structured-wall thermoplastics pipes \u2014 Oven test<\/td>\n<td>ISO 12091:1995<\/td>\n<\/tr>\n<tr>\n<td>Plastics piping and ducting systems &#8211; Thermoplastics pipes &#8211; Determination of ring flexibility<\/td>\n<td>UNI EN 1446:1998<\/td>\n<\/tr>\n<tr>\n<td>Resistance to water pressure (During cleaning and maintenance)<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Plastics piping systems for non-pressure underground drainage and sewerage &#8211; Unplasticized poly(vinyl chloride) (PVC-U) &#8211; Part 1: Specifications for pipes, fittings and the system-PVC-U<\/td>\n<td>EN 1401-1:2019<\/td>\n<\/tr>\n<tr>\n<td>Explosion resistant equipmen<\/td>\n<td>EN 14460:2018<\/td>\n<\/tr>\n<tr>\n<td>Plastics piping systems for water supplay, and for drainage and sewerage under pressure \u2013 Polyethylene (PE)<\/td>\n<td>EN 12201-2:2011<\/td>\n<\/tr>\n<tr>\n<td>Hidrostatic strength at 20 -80*C<\/td>\n<td>EN ISO 1167-1-2<\/td>\n<\/tr>\n<tr>\n<td>Thermoplastics pipes \u2013 Longitudinal reversion \u2013 Test method and parameters<\/td>\n<td>EN ISO 2505<\/td>\n<\/tr>\n<tr>\n<td>Elongation at break<\/td>\n<td>EN ISO 6259-1-3:1997<\/td>\n<\/tr>\n<tr>\n<td>Plastic-Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics<\/td>\n<td>UNI EN ISO 1133-1:2022<\/td>\n<\/tr>\n<tr>\n<td>Plastics-Methods for determining the density of non-cellular plastics<\/td>\n<td>UNI EN ISO 1183-1:2019<\/td>\n<\/tr>\n<tr>\n<td>Plastics piping systems- Plastics components- Determination of dimensions<\/td>\n<td>EN ISO 3126:2005<\/td>\n<\/tr>\n<tr>\n<td>Thermoplastics pipes \u2013 Determination of resistance to external blows \u2013 Round \u2013 the \u2013 clock method. UNI EN ISO 3127:2018<\/td>\n<td>UNI EN ISO 3127:2018<\/td>\n<\/tr>\n<tr>\n<td>Polyethilene (PE) piprd snd fittings \u2013 Determination of the tensile strength and failure mode of test pieces from a butt-fused joint<\/td>\n<td>ISO 13953: 2001<\/td>\n<\/tr>\n<tr>\n<td>Plastics pipes and fittings \u2013 Peel decohesion test for polyethylene (PE) electrofusion assemblies of nominal outside diameter reater than or equal to 90 mm<\/td>\n<td>ISO 13954:1997<\/td>\n<\/tr>\n<tr>\n<td>Plastics pipes and fittings \u2013 Crushing decohesion test for polyethylene (PE) electrofusion assemblies<\/td>\n<td>ISO 13955:1997<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/h6><\/div><\/div><\/div><\/div><\/div><\/div>\r\n\t<div class=\"bauer-spacer clearfix\" data-desktop=\"40\" data-mobi=\"40\" data-smobi=\"40\"><\/div><\/div><\/div><\/div><\/div><\/div><\/section><\/div>\n<\/section>","protected":false},"excerpt":{"rendered":"Laboratori i Teqja Internacional Laboratori i Teqja Internacional \u00ebsht\u00eb nj\u00eb ambient i specializuar i cili p\u00ebrdoret p\u00ebr t\u00eb testuar dhe monitoruar cil\u00ebsin\u00eb e produkteve. Laboratori \u00ebsht\u00eb i pajisur me teknologji t\u00eb avancuar dhe paisje shtes\u00eb p\u00ebr t\u00eb siguruar q\u00eb produktet e tyre t\u00eb plot\u00ebsojn\u00eb standarde t\u00eb larta cil\u00ebsie dhe sigurie.","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-9706","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/teqja.com.al\/en\/wp-json\/wp\/v2\/pages\/9706","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/teqja.com.al\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/teqja.com.al\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/teqja.com.al\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/teqja.com.al\/en\/wp-json\/wp\/v2\/comments?post=9706"}],"version-history":[{"count":9,"href":"https:\/\/teqja.com.al\/en\/wp-json\/wp\/v2\/pages\/9706\/revisions"}],"predecessor-version":[{"id":9755,"href":"https:\/\/teqja.com.al\/en\/wp-json\/wp\/v2\/pages\/9706\/revisions\/9755"}],"wp:attachment":[{"href":"https:\/\/teqja.com.al\/en\/wp-json\/wp\/v2\/media?parent=9706"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}